The Baker Company SterilGARD e3 SG604 Class II Type A2 Biological Safety Cabinet
Used, with a known minor cosmetic or mechanical defect, or a repair that may be needed. Still a valuable unit, but expect a modest investment to bring it back to full condition.
The Baker Company
Questions about this item? Call us (760) 560-0013
Details
-
CategoryBiosafety Cabinets
-
Dimension31.0in x 77.0in x 84.0in
-
Serial127853
-
Shipping TypeFreight
-
Voltage / Hertz115V / 60Hz US
Description
The Baker Company SterilGARD e3 SG604 Class II Type A2 Biological Safety Cabinet is a vertical laminar airflow biosafety enclosure designed to provide personnel, product, and environmental protection for aseptic cell culture, microbiology, and clinical research workflows. The cabinet uses HEPA-filtered supply and exhaust airflow with a Class II Type A2 airflow arrangement, supporting clean work practices inside the work zone. It is NSF/ANSI 49 listed for the Type A2 configuration and is intended for laboratory biological work where containment and sterile technique are required. Condition notes: This unit is preowned from a working laboratory environment. The fluorescent light and blower are working. An active alarm is present with the alarm light illuminated and a three-beep alarm pattern that continues even after setting the sash to the correct height level. UV light is not installed. Expect minor repair or service may be needed to address the alarm behavior.
Technician comment
Preowned from a working laboratory environment. The fluorescent light and blower are working. The unit has an active alarm with the alarm light illuminated and three-beep alarm pattern even after setting sash at correct height level. UV light is not installed. Please review all photos carefully for additional condition details.
Key Features
- Class II Type A2 biological safety cabinet airflow design
- Vertical laminar downflow with front inflow containment
- HEPA-filtered supply and exhaust airflow
- Ergonomic front access for routine sterile technique tasks
- NSF/ANSI 49 listed configuration for Type A2
Specifications
- Voltage: 115V
- Hertz: 60Hz US
- Cabinet class: Class II, Type A2 biological safety cabinet
- Airflow type: vertical laminar downflow with front inflow containment
- HEPA/ULPA filtration: HEPA-filtered supply and exhaust airflow
- Exhaust configuration: recirculating Type A2 configuration with optional external exhaust connection when properly configured
- Certifications: NSF/ANSI 49 listed configuration
- Weight: approx. 771 lbs.
Weight
Imperial: 750.0 Pounds
Metric: 340.19 Kilograms
Shipping Dimensions
Imperial: 37.2 in x 92.4 in x 100.8 in
Metric: 94.49 cm x 234.7 cm x 256.03 cm
Product Enquiry
Have a question about this product? Send us your enquiry and our sales team will get back to you shortly.
Inform me when available
This item has sold. Leave your details and we will get in touch when a similar model becomes available.